Eficacia de la obturación ortógrada de conductos radiculares con MTA vs. MTA más conos de gutapercha

Autores/as

  • Pedro Pablo Mejía Fernández Universidad Metropolitana
  • Karen Bustos Molina Universidad Metropolitana

Resumen

 

Objetivo: Evaluar la capacidad del sellado del MTA usado como material único de sellado o usándolo como cemento sellador más conos de gutapercha.
Materiales y métodos: Se seleccionaron las raíces mesiales de 24 molares inferiores y se instrumentaron hasta una lima maestra apical # 40 con la técnica de Crown Down. El grupo I fue obturado con conos de gutapercha y el MTA fue usado como cemento sellador; el grupo II fue obturado con MTA solamente. Se utilizaron cuatro raíces como control positivo y negativo; las muestras fueron cubiertas con cera pegajosa, dejando libre solo los dos últimos milímetros apicales, se centrifugaron en tinta china durante una hora y se les realizó procedimiento de transparentación, para posteriormente medir la microfiltración con un microscopio estereoscópico.

Resultados: Los resultados fueron analizados estadísticamente con el test de KRUSKAL- WALLIS para variables independientes, y no se encontró diferencia estadísticamente signi- ficativa entre los dos grupos.
Conclusiones: No se encontró diferencia estadísticamente significativa entre los dos gru- pos. En situaciones clínicas que no permiten la obturación convencional con conos de gutapercha, cualquiera de las dos técnicas de colocación del MTA son factibles.

Palabras clave: Microfiltracion, mineral trióxido agregado (MTA), obturación.

 

Abstract

Objetives: This study evaluated the sealing capability of MTA when it is used as the only root canal filling material and when it is used as sealing cement combined with gutapercha points.
Materials and methods: The mesial roots of 24 inferior molars were selected; they were instrumented until an apical master file # 40 with Crown Down technique. Group I were obtured with gutapercha points and MTA as sealing cement; group II were obtured only with MTA. Four roots were used as positive and negative control, samples were covered with sticky wax, leaving free the apical last 2 mm, they were centrifugued with chinese ink for one hour and then they were turned transparent, to measure the microleakage with a stereoscopic microscope.

Results: Results were analyzed statistically with the KRUSKAL-WALLIS test for inde- pendent variables and statistically no significant difference was found between the two groups.
Conclusion: Statistically no significant difference was found between the two groups. In such clinical situations that don't permit conventional obturation with gutapercha points, both MTA techniques are viable.

Keywords: Microleakage, mineral trioxide aggregate (MTA), obturation.

 

 

Descargas

Publicado

2012-10-21

Cómo citar

Mejía Fernández, P. P., & Bustos Molina, K. (2012). Eficacia de la obturación ortógrada de conductos radiculares con MTA vs. MTA más conos de gutapercha. Revista Científica Salud Uninorte, 28(3). Recuperado a partir de https://rcientificas.uninorte.edu.co/index.php/salud/article/view/4756

Número

Sección

Artículo Original

Artículos más leídos del mismo autor/a